לשיחה עם נציג
תפריט

    לפרטים נוספים עבור גיזוגראונד Gisoground PCI נא מלאו את הטופס:

    • תיאור ותכונות

      • Solvent-free to TRGS 610; Giscode D1
      • EU 2004/42/IIA(g)(50/30): < 15 g/l.
      • Improves the strength and solidity of substrates and helps increase adhesion of tiles, plasters and wallpapers
      • Reliable adhesion of PCI tile adhesives to PCI Gisogrund primer
      • Protects thin-bed mortars and levelling compounds from too rapid dehydration on absorbent substrates, extends the open time, improves adhesion and prevents formation of cracks caused by shrinkage
      • Prevents formation of blow holes and too rapid dehydration when levelling floors with PCI Periplan, PCI Periplan fein or PCI Periplan Tixo
      • Protects calcium sulphate (anhydrite) screeds from forming ettringite
      • Enables wallpaper to be easily removed
      • Complies with the guidelines issued by Bundesverband der Gipsbauplatten- und Gipsindustrie (German gypsum industry association)
    • שימושים

      • For indoor and outdoor use.
      • For walls and floors
      • Primer for absorbent substrates to protect subsequent material from too rapid dehydration
      • Primer prior to the application of flowable and non-sag floor levelling compounds, e.g. PCI Periplan, PCI Periplan fein or PCI Periplan Tixo and other mortars and anhydrite screeds which set through hydration
      • Primer for anhydrite screeds and building boards
      • Primer for mastic asphalt screeds prior to the application of PCI tile adhesives
      • Primer to strengthen mealy, absorbent screed surfaces and plasters indoors prior to the laying of tiles and mosaic
      • Acting as a moisture barrier and primer for plaster, plaster slabs, gypsum fibre boards, plaster boards, aerated concrete, concrete, asphalt, render and brickwork before tiling and wallpapering
      • Primer for aerated concrete and brickwork on walls prior to the application of plaster and gypsum lime plaster
    • נתונים טכניים

      MATERIAL
      Material basemodified acrylic resin dispersion
      Componentssingle-component
      Densityapprox. 1.0 g/cm³
      Control colourblue
      Labelling to:
      - Carriage of Dangerous Goods by Road, Rail and Inland Waterways

      - Regulation for hazardous substances

      non hazardous

      no labelling requirement for this product

      Shelf lifemin. 12 months
      Storagein dry conditions, no permanent storage over +30°C, but not below -10°C. Frozen PCI Gisogrund should be slowly thawn and stirred thoroughly.
      Packaging size200 l barrel

      20 l pail

      10 l pail

      5 l pail

      1 l bag

      APPLICATION
      SubstrateConsumptionMixing ratio
      Gypsum based substrates; anhydrite screeds, mastic asphalt screeds, xylolith screeds; screeds with old adhesive residuesapprox. 80 to 150 ml/m²undiluted
      Absorbent mineral substrates, e.g. concrete, cement screeds, gauged renders, aerated concrete, limestone or similar1st coat

      approx. 100 to 200 ml/m² (200 to 400 ml undiluted mix)

      2nd coat

      approx. 50 to 70 ml/m² (100 to 140 ml undiluted mix)

      1st coat

      diluted 1 : 1 with water

      2nd coat:

      diluted 1 : 1 with water

      Coverage20 l pail covers10 l pail covers5 l pail covers1 l bag covers
      Gypsum based substrates; anhydrite screeds, mastic asphalt screeds, xylolith screeds; screeds with old waterproof adhesive residuesapprox. 130 to 250 m²approx. 65 to 125 m²approx. 33 to 62 m²approx. 6.5 to 12.5 m²
      Absorbent mineral substrates, e.g. concrete, cement screeds, gauged renders, aerated concrete, limestone or similar100 - 200 m² for one coat;
      74 - 130 m² for two coats
      50 - 100 m² for one coat;

      37 - 65 m² for two coats

      25 - 50 m² for one coat;

      19 - 33 m² for two coats

      5 – 10 m² for one coat;

      3.7 - 6.5 m² for two coats

      Working temperature+5°C to +30°C

      (substrate temperature)

      Curing times*
      - walkable afterapprox. 30 - 60 minutes
      - 2nd coat afterapprox. 30 - 60 minutes
      - subsequent application afterapprox. 60 - 180 minutes (depending on the absorbency of the substrate as well as temperature and humidity)
      Temperature resistance of cured film-20°C to +80°C
      * At +23°C and 50% relative humidity. Higher temperatures reduce, lower temperatures increase the times given. Higher humidity increases the times given.

    לפרטים נוספים עבור גיזוגראונד Gisoground PCI נא מלאו את הטופס: